Mahindra Powerol Genset

Prominent & Leading OEM Manufacturer from Jaipur, we offer 160 kva mahindra powerol genset, 180 kva mahindra powerol genset, 50 kva mahindra powerol genset, 82.5 kva mahindra powerol genset, 125 kva mahindra powerol genset and 25 kva mahindra powerol genset.

160 kVA Mahindra Powerol Genset

  • Foil Print

₹ 9.80 Lakh /Piece Get Latest Price

Product Brochure
Power (kVA)160 kVA
Genset BrandMahindra Powerol
Phase3 Phase
Fuel Consumption (at 100% Load)36.7 ltr/hr
Fuel Tank Capacity388 litres
Dry Weight (Kg)2425
Frequency50 Hz
Engine ModelmPower61995G

PARAMETERSDG MODELS
Parameters DG Model
50 Hz Prime Rating(kVA) 160 180 200
Rated (KWe) 128 144 160
Engine Model mPower61995G mPower62235G mPower62485G
No of Cylinders 6 6 6
Phase / Voltage (V) 3 / 415
Power Factor 0.8 (lagging)
Current (A) 222.4 250.2 278
Frequency (Hz)& RPM 50/1500

180 kVA Mahindra Powerol Genset

  • Foil Print

₹ 12.85 Lakh /Piece Get Latest Price

Product Brochure
Power (kVA)180 kVA
Genset BrandMahindra Powerol
Phase3 Phase
Fuel Consumption (at 100% Load)38.2 ltr/hr
Fuel Tank Capacity388 litres
Dry Weight (Kg)2630
Frequency50 Hz

PARAMETERSDG MODELS
Parameters DG Model
50 Hz Prime Rating(kVA) 160 180 200
Rated (KWe) 128 144 160
Engine Model mPower61995G mPower62235G mPower62485G
No of Cylinders 6 6 6
Phase / Voltage (V) 3 / 415
Power Factor 0.8 (lagging)
Current (A) 222.4 250.2 278
Frequency (Hz)& RPM 50/1500

50 kVA Mahindra Powerol Genset

  • Foil Print

₹ 4.75 Lakh /Piece Get Latest Price

Product Brochure
Power (kVA)50 kVA
Genset BrandMahindra Powerol
Phase3 Phase
Fuel Consumption (at 100% Load)12.4 ltr/hr
Fuel Tank Capacity185 litres
Dry Weight (Kg)1258
Frequency50 Hz
Engine Model4725GM-C2

PARAMETERSDG MODELS
Duty (Standby/ Prime) Prime Prime
50 HZ PRIME Rating(kVA) 50 kVA 62.5 kVA
Rated(kWe) 40 50
Engine Model 4725GMAC2 4905GMAC2
Power Factor (lagging) 0.8 0.8
Governing class G2 G2
Starting system 12 V DC Elec 12 V DC Elec

82.5 kVA Mahindra Powerol Genset

  • Foil Print

₹ 5.95 Lakh /Piece Get Latest Price

Product Brochure
Power (kVA)82.5 kVA
Genset BrandMahindra Powerol
Phase3 Phase
Fuel Consumption (at 100% Load)18.1 ltr/hr
Fuel Tank Capacity160 litres
Dry Weight (Kg)1500
Frequency50 Hz

PARAMETERSDG MODELS
Duty (Standby/ Prime) Prime Prime Prime Prime
50 HZ PRIME Rating(kVA) 75 kVA 82.5 kVA 100 kVA 125 kVA
Rated(kWe) 60 66 80 100
Engine Model 41035 GM-C2 41125A GM-C2 mPower41265G mPower41565G mPower61565G
No of Cylinders 4 4 4 4 6
Phase / Voltage (V) 3 / 415 3 / 415 3 / 415 3 / 415 3 / 415
Power Factor 0.8 (lagging)
Current (A) 104.4 114.8 139 173.7
Governing class G2
Starting system 12 V DC Elec 12 V DC Elec 12 V DC Elec 24 V DC Elec
Fuel tank capacity 180 160 250
Genset Dimension (LxWxH $$) (mm) Approx. 3000 X 1150 X 2135 2950 X 1075 X 1575 3500 x 1230 x 1425
Genset Weight (kg) approx. 1350 1500 1650 1650 1855
Rated Speed RPM 50/1500

125 kVA Mahindra Powerol Genset

  • Foil Print

₹ 7.45 Lakh /Piece Get Latest Price

Product Brochure
Power (kVA)125 kVA
Genset BrandMahindra Powerol
Phase3 Phase
Fuel Consumption (at 100% Load)28 ltr/hr
Fuel Tank Capacity250 Litres
Dry Weight (Kg)1855
Frequency50 Hz
Governing classG2 As Per ISO 8528 Part V

PARAMETERSDG MODELS
Duty (Standby/ Prime) Prime Prime Prime Prime
50 HZ PRIME Rating(kVA) 75 kVA 82.5 kVA 100 kVA 125 kVA
Rated(kWe) 60 66 80 100
Engine Model 41035 GM-C2 41125A GM-C2 mPower41265G mPower41565G mPower61565G
No of Cylinders 4 4 4 4 6
Phase / Voltage (V) 3 / 415 3 / 415 3 / 415 3 / 415 3 / 415
Power Factor 0.8 (lagging)
Current (A) 104.4 114.8 139 173.7

25 kVA Mahindra Powerol Genset

  • Foil Print

₹ 3.50 Lakh /Piece Get Latest Price

Product Brochure
Power (kVA)25 kVA
Genset BrandMahindra Powerol
Phase3 Phase
Fuel Consumption (at 100% Load)6.2 ltr/hr
Fuel Tank Capacity75 Litres
Dry Weight (Kg)786
Frequency50 Hz
Engine Model3385TCIGM-C2

PARAMETERSDG MODELS
Duty (Standby/ Prime) Stand By Prime Prime
50 HZ PRIME Rating(kVA) 20 kVA 22.5 kVA 25 kVA
Rated(kWe) 16 18 20
Engine Model 3285 GM-C2 3335 TCGM-C2 3385 ELSTCGMC2
No of Phases 1/3 1/3 1/3
Output Voltage (V) 230/415 230/415 230/415
Power Factor (lagging) 0.8 0.8 0.8

250 kVA Mahindra Powerol Genset

  • Foil Print

Get Latest Price

Product Brochure
Power (kVA)250 kVA
Genset BrandMahindra Powerol
Model NumberEngine model 63105G
Engine MakeMahindra
Phase3-Phase
Fuel Consumption (at 100% Load)54.1 Ltr/hr
Fuel Tank Capacity425 Litres
Dry Weight (Kg)3300
Frequency50 Hz
Governing classG2 as per ISO 8528 Part V

Genset Specification
Genset Prime Rating (kVA) * 250 320
Genset Prime Rating (KW) 200 256
Phase / Voltage (V) 3 / 415 3 / 415
Power Factor 0.8 (lagging) 0.8 (lagging)
Current (A) (3Phase) 348 445
Frequency (Hz)& RPM 50/1500 50/1500
Governing class G2 G2
Starting system 24 V DC Elec 24 V DC Elec
Fuel tank capacity 425 570
Genset Dimension (LxWxH) (mm) Approx. 3990 x 1500 x 1770 4550 X 1600 X 1780
Genset Weight (kg) approx. 3300 3550
Engine Specification
Make / Series Mahindra mPower Mahindra mPower
Engine Model mPower63105G mPower63905G
Rated Power at 100% Load @ 1500 RPM (HP) 310 390

500 kVA Mahindra Powerol Genset

  • Foil Print

Get Latest Price

Product Brochure
Power (kVA)500 kVA
Genset BrandMahindra Powerol
Phase3 Phase
Fuel Consumption (at 100% Load)101 ltr/hr
Fuel Tank Capacity700 Litres
Dry Weight (Kg)5800
Frequency50 Hz
Engine Model2506D-E15TAG2

Features Mahindra 
Genset Rating ( kVA) 500
Engine Model No. 2506D-E15TAG2(Perkins)
No. of Cylinder 6 Inline
Displacement (Ltr) 15.2
BHP 607
DG Dimensions (Foot print) 5000 x 1900 x 2350
Dry Genset Weight (Kg) 5800
Governor Electronic 
Governing Class G2 Governing class As per ISO 8528 part V
Fuel system MEUI fuel system
Calibration of Fuel Pump Not needed
BMEP(in Bar) 23.82
Average Load Factor 80%
Fuel Consumption @ 100% load 101
Fuel Consumption @ 75% load 78.6
Unit Generated per lire @ 75% load 3.82
Cost per unit 18.43
Total Lubrication System Capacity(in Ltr) 62
Lube Oil Consumption at rated load (Lit/hr) 0.101
Lube Oil Change Period 500 hrs
Coolant Capacity(in Ltr) 52
Fuel Tank Capacity (in Ltr) 750
Telematics Yes
Controller  DSE 4520 R1

100 kVA Mahindra Powerol Genset

  • Foil Print

Get Latest Price

Product Brochure
Phase3-Phase
Engine MakeMahindra
Model NumbermPower41265G
Genset BrandMahindra Powerol
Power (kVA)100 kVA
Frequency50 Hz
Dry Weight (Kg)1650
Fuel Tank Capacity250 Litres
Fuel Consumption (at 100% Load)23.1 ltr/hr

PARAMETERSDG MODELS
Duty (Standby/ Prime) Prime Prime Prime Prime
50 HZ PRIME Rating(kVA) 75 kVA 82.5 kVA 100 kVA 125 kVA
Rated(kWe) 60 66 80 100
Engine Model 41035 GM-C2 41125A GM-C2 mPower41265G mPower41565G mPower61565G
No of Cylinders 4 4 4 4 6
Phase / Voltage (V) 3 / 415 3 / 415 3 / 415 3 / 415 3 / 415
Power Factor 0.8 (lagging)
Current (A) 104.4 114.8 139 173.7
Governing class G2
Starting system 12 V DC Elec 12 V DC Elec 12 V DC Elec 24 V DC Elec

45 kVA Mahindra Powerol Genset

  • Foil Print

Get Latest Price

Product Brochure
Power (kVA)45 kVA
Genset BrandMahindra Powerol
Phase3 Phase
Fuel Tank Capacity115 Litres
Dry Weight (Kg)996
Frequency50 Hz

PARAMETERSDG MODELS
Duty (Standby/ Prime) Prime Stand By Stand By Prime Stand By
50 HZ PRIME Rating(kVA) 30 kVA 30 kVA 35 kVA 40 kVA 45 kVA
Rated(kWe) 24 24 35 32 36
Engine Model 3445TCIGM-C2 3385 ELSTCGMC2 3445 TCIGM-C2 4575 TCIGM-C2 4575TCIGM-C2
No of Phases 1/3 1/3 1/3 1/3 1/3
No of Cylinders 3 3 3 4 4
Output Voltage (V) 230V/415V 230V/415V 230V/415V 230V/415V 230V/415V

62.5 kVA Mahindra Powerol Genset

  • Foil Print

Get Latest Price

Product Brochure
Power (kVA)62.k kVA
Genset BrandMahindra Powerol
Phase3 Phase
Fuel Consumption (at 100% Load)15.3 ltr/hr
Dry Weight (Kg)1293
Frequency50 Hz
Engine Model4905GM-C2

PARAMETERSDG MODELS
Duty (Standby/ Prime) Prime Prime
50 HZ PRIME Rating(kVA) 50 kVA 62.5 kVA
Rated(kWe) 40 50
Engine Model 4725GMAC2 4905GMAC2
Power Factor (lagging) 0.8 0.8
Governing class G2 G2
Starting system 12 V DC Elec 12 V DC Elec

15 kVA Mahindra Powerol Genset

  • Foil Print

Get Latest Price

Product Brochure
Power (kVA)15 kVA
Genset BrandMahindra Powerol
Phase3 Phase
Fuel Consumption (at 100% Load)3.6 ltr/hr
Fuel Tank Capacity55 Litres
Dry Weight (Kg)673
Frequency50 Hz
Engine Model3255 GM C2

PARAMETERSDG MODELS
Duty (Standby/ Prime) Prime
50 HZ PRIME Rating(kVA) 10 kVA
Rated(kWe) 8
Engine Model 2185GM-C2
No of Cylinders 2
No of Phases 1/3
Output Voltage (V) 230/415
Power Factor (lagging) 0.8
Current (A) (1Phase / 3Phase) 43.5/13.9

62.5 kVA Mahindra Powerol Genset

  • Foil Print

Get Latest Price

Product Brochure
Power (kVA)62.k kVA
Genset BrandMahindra Powerol
Phase3 Phase
Fuel Consumption (at 100% Load)15.3 ltr/hr
Fuel Tank Capacity185 Litres
Dry Weight (Kg)1293
Frequency50 Hz
Radiator coolant capacity55.6L

PARAMETERSDG MODELS
Duty (Standby/ Prime) Prime Prime
50 HZ PRIME Rating(kVA) 50 kVA 62.5 kVA
Rated(kWe) 40 50
Engine Model 4725GMAC2 4905GMAC2
Power Factor (lagging) 0.8 0.8
Governing class G2 G2
Starting system 12 V DC Elec 12 V DC Elec
Intergrated Fuel Tank Capacity (lits) 185 185
Genset Dimension (LxWxH $$) (mm) Approx. 2400 X 1050 X 1523 2400 X 1050 X 1523
Genset Weight (Kg), Appx 1258 1293
Make Mahindra Mahindra

200 kVA Mahindra Powerol Genset

  • Foil Print

Get Latest Price

Product Brochure
Power (kVA)200 kVA
Genset BrandMahindra Powerol
Phase3 Phase
Fuel Consumption (at 100% Load)40.8 ltr/hr
Fuel Tank Capacity388 litres
Dry Weight (Kg)2630
Frequency50 Hz
Engine ModelmPower62485G
Lube oil specification15W40 API CI4+

PARAMETERSDG MODELS
Parameters DG Model
50 Hz Prime Rating(kVA) 160 180 200
Rated (KWe) 128 144 160
Engine Model mPower61995G mPower62235G mPower62485G
No of Cylinders 6 6 6
Phase / Voltage (V) 3 / 415
Power Factor 0.8 (lagging)
Current (A) 222.4 250.2 278
Frequency (Hz)& RPM 50/1500
Governing class G2

Mahindra Powerol 10 KVA Genset

  • Foil Print

Get Latest Price

Product Brochure
Power (kVA)10 kVA
Genset BrandMahindra Powerol
Phase3 Phase
Fuel Consumption (at 100% Load)2.9 ltr/hr
Fuel Tank Capacity55 Litres
Dry Weight (Kg)633
Frequency50 Hz
Engine Model2185GM-C2

PARAMETERSDG MODELS
Duty (Standby/ Prime) Prime
50 HZ PRIME Rating(kVA) 10 kVA
Rated(kWe) 8
Engine Model 2185GM-C2
No of Cylinders 2
No of Phases 1/3
Output Voltage (V) 230/415
Power Factor (lagging) 0.8
Current (A) (1Phase / 3Phase) 43.5/13.9
Frequency (Hz)/ RPM 50/1500

20 kVA Mahindra Powerol Genset

  • Foil Print

Get Latest Price

Product Brochure
Fuel TypeDiesel
Voltage415V
Power20KVA
Number Of Phase3 Phase
Number Of Cylinder3
Country of OriginMade in India
Engine Model3285GM-C2
BrandMahindra

PARAMETERSDG MODELS
Duty (Standby/ Prime) Stand By Prime Prime
50 HZ PRIME Rating(kVA) 20 kVA 22.5 kVA 25 kVA
Rated(kWe) 16 18 20
Engine Model 3285 GM-C2 3335 TCGM-C2 3385 ELSTCGMC2
No of Phases 1/3 1/3 1/3
Output Voltage (V) 230/415 230/415 230/415
Power Factor (lagging) 0.8 0.8 0.8
Current (A) (1Phase / 3Phase) 87/27.8 97.8 / 31.3 108.7/34.8
Frequency (Hz)/ RPM 50/1500 50/1500 50/1500

30 kVA Mahindra Powerol Genset

  • Foil Print

Get Latest Price

Product Brochure
Power (kVA)30 kVA
Genset BrandMahindra Powerol
Phase3 Phase
Weight950kg
Fuel Tank Capacity115 Litres
Dry Weight (Kg)935
Frequency50 Hz
Engine Model3445TCIGM-C2

PARAMETERSDG MODELS
Duty (Standby/ Prime) Prime Stand By Stand By Prime Stand By
50 HZ PRIME Rating(kVA) 30 kVA 30 kVA 35 kVA 40 kVA 45 kVA
Rated(kWe) 24 24 35 32 36
Engine Model 3445TCIGM-C2 3385 ELSTCGMC2 3445 TCIGM-C2 4575 TCIGM-C2 4575TCIGM-C2
No of Phases 1/3 1/3 1/3 1/3 1/3
No of Cylinders 3 3 3 4 4
Output Voltage (V) 230V/415V 230V/415V 230V/415V 230V/415V 230V/415V
Current (A) (1Phase / 3Phase) 130.4/ 41.7 130.4/ 41.7 152.2 / 48.7 173.9 / 55.7 195.7/62.6
Power Factor (lagging) 0.8 0.8 0.8 0.8 0.8
Frequency (Hz)/ RPM 50/1500 50/1500 50/1500 50/1500 50/1500
Governing class A1 A1 A1 A1 G2
Starting system 12 V DC Elec 12 V DC Elec 12 V DC Elec 12 V DC Elec 12 V DC Elec

35 kVA Mahindra Powerol Silent Gensets

  • Foil Print

Get Latest Price

Product Brochure
Power (kVA)35 kVA
Genset BrandMahindra Powerol
Phase3 Phase
Fuel Tank Capacity115 Litres
Dry Weight (Kg)926
Frequency50 Hz

Duty (Standby/ Prime) Prime Stand By Stand By Prime Stand By
50 HZ PRIME Rating(kVA) 30 kVA 30 kVA 35 kVA 40 kVA 45 kVA
Rated(kWe) 24 24 35 32 36
Engine Model 3445TCIGM-C2 3385 ELSTCGMC2 3445 TCIGM-C2 4575 TCIGM-C2 4575TCIGM-C2
No of Phases 1/3 1/3 1/3 1/3 1/3
No of Cylinders 3 3 3 4 4
Output Voltage (V) 230V/415V 230V/415V 230V/415V 230V/415V 230V/415V
Current (A) (1Phase / 3Phase) 130.4/ 41.7 130.4/ 41.7 152.2 / 48.7 173.9 / 55.7 195.7/62.6

30 kVA Mahindra Powerol Genset

  • Foil Print

Get Latest Price

Product Brochure
Power (kVA)30 kVA
Genset BrandMahindra Powerol
Phase3 Phase
Fuel Consumption (at 100% Load)7.3 ltr/hr
Fuel Tank Capacity115 Litres
Dry Weight (Kg)935
Frequency50 Hz
Engine ModelmPower63905G
Lube oil specification15W40 API CI4+

PARAMETERSDG MODELS
Duty (Standby/ Prime) Prime Stand By Stand By Prime Stand By
50 HZ PRIME Rating(kVA) 30 kVA 30 kVA 35 kVA 40 kVA 45 kVA
Rated(kWe) 24 24 35 32 36
Engine Model 3445TCIGM-C2 3385 ELSTCGMC2 3445 TCIGM-C2 4575 TCIGM-C2 4575TCIGM-C2
No of Phases 1/3 1/3 1/3 1/3 1/3
No of Cylinders 3 3 3 4 4
Output Voltage (V) 230V/415V 230V/415V 230V/415V 230V/415V 230V/415V
Current (A) (1Phase / 3Phase) 130.4/ 41.7 130.4/ 41.7 152.2 / 48.7 173.9 / 55.7 195.7/62.6
Power Factor (lagging) 0.8 0.8 0.8 0.8 0.8

400 kVA Mahindra Powerol Genset

  • Foil Print

Get Latest Price

Product Brochure
Power (kVA)400 kVA
Genset BrandMahindra Powerol
Phase3 Phase
Fuel Consumption (at 100% Load)90.5 ltr/hr
Dry Weight (Kg)5200
Frequency50 Hz

Genset Prime Rating (kVA) * 400 500 625
Genset Prime Rating (KW) 320 400 500
Phase / Voltage (V) 3/415
Power Factor 0.8 (lagging)
Current (A) 556 695 869
Frequency (Hz)& RPM 50/1500
Governing class G2 G2 G2
Starting system 24 V DC Electrical
Fuel tank capacity (lit) 700 800
Genset dimensions w/o silencer (mm) (L x W x H) approx. 5000x1900x2302 5850 X 2000 X 2300
Genset Weight (kg) approx.

5 KVA Mahindra Powerol Genset

  • Foil Print

Get Latest Price

Product Brochure
Power (kVA)5 kVA
Genset BrandMahindra Powerol
Phase3 Phase
Fuel Tank Capacity15 Litres
Dry Weight (Kg)210
Frequency50 Hz

Genset 5 kVA
Rating @ 0.8 pf (kVA) 5 kVA
Control Panel AMF/MCP
Genset dimensions L x W x H (mm) 1050 x 620 x 745
Fuel tank capacity (in Ltrs.) 15
Weight (Kg) 210
Engine
Engine Model M/s. Lombardini (KD441-GSI2)
Type Direct Injection
Rated Power (BHP) 8.2

75 kVA Mahindra Powerol Genset

  • Foil Print

Get Latest Price

Product Brochure
Power (kVA)75 kVA
Genset BrandMahindra Powerol
Phase3 Phase
Fuel Consumption (at 100% Load)17.8 Ltr/hr
Fuel Tank Capacity180 Litres
Dry Weight (Kg)1350
Frequency50 Hz
Engine Model41035GM-C2

PARAMETERSDG MODELS
Duty (Standby/ Prime) Prime Prime Prime Prime
50 HZ PRIME Rating(kVA) 75 kVA 82.5 kVA 100 kVA 125 kVA
Rated(kWe) 60 66 80 100
Engine Model 41035 GM-C2 41125A GM-C2 mPower41265G mPower41565G mPower61565G
No of Cylinders 4 4 4 4 6
Phase / Voltage (V) 3 / 415 3 / 415 3 / 415 3 / 415 3 / 415
Power Factor 0.8 (lagging)
Current (A) 104.4 114.8 139 173.7
Governing class G2
Starting system 12 V DC Elec 12 V DC Elec 12 V DC Elec 24 V DC Elec

Silent Diesel Generator Set

  • Foil Print

Get Latest Price

Product Brochure
Power (kVA)100
Genset BrandMahindra Powerol
Model NumbermPower41265G
Phase3-Phase
Centre lifting DG set dimensions with top hoodNA
Canopy Dimension L X W X HNA
Canopy Dimensions (L x W x H)NA
Dimensions(L X W X H)NA
Side Lifting DG Set DimensionsNA

Minimum order quantity: 1 Number

Sr. No. Specification Quantity Mahindra
  Engine Model   100KVA
ENGINE No Of Cylinders   4
BHP HP 126
RPM RPM 1500
Stroke   4
Bore *Stroke  MM 105*137
Displacement lit 4.8
Compression Ratio   16.8:1
Governing system   A1
Cooling System Coolant Capacity    Water Cooled
Cooling System Coolant Capacity  Liters 17
Fuel consumption at 100% in Ltr/Hr Liters 23.1
Fuel consumption  at 75% in Ltr/Hr Liters 17.3
Lube oil consumption Liter/HR 0.1
Lube oil change Period HRS 500
Lub Oil system capacity (with filters) Liters 13.5
Aspiration   TC
Battery  Volts Volts 12
Battery Capacity AH 150
CANOPY Length mm 3200
width mm 1300
Height mm 1700
weight kg 1700
Fuel tank capacity Liters 250
SERVICE COST Fuel filter Cost Rs 569
oil filter cost Rs 424
oil cost Rs 2835
Total   3828

Mahindra Silent Diesel Generator

  • Foil Print

Get Latest Price

Product Brochure
Power (kVA)20 kva
Genset BrandMahindra Powerol
Model Number3285
Engine MakeMahindra
Phase3-Phase
Centre lifting DG set dimensions with top hoodNA
Canopy Dimension L X W X HNA
Canopy Dimensions (L x W x H)NA
Dimensions(L X W X H)NA
Side Lifting DG Set DimensionsNA
Centre Lifting DG Set DimensionNA
Lube Oil Refil Quantity (Lit)NA
Dimensions (L x W x H)NA
Dimensions (W X H X D)NA
Dimension (L X W X H)NA

Minimum order quantity: 1 per piece

Sr. No. Specification Quantity Mahindra
  Engine Model   3285GM C2
ENGINE No Of Cylinders   3
BHP HP 28
RPM RPM 1500
Stroke   4
Bore *Stroke  MM 88.9 x 110
Displacement CC 2.04
Compression Ratio   19.5:1
Governing system   A1
Cooling System    Water Cooled
Cooling System Coolant Capacity  Liters 11
Fuel consumption at 100% in Ltr/Hr Liters 4.98
Fuel consumption  at 75% in Ltr/Hr Liters 3.74
Fuel consumption  at 50% in Ltr/Hr Liters 2.63
Lube oil consumption Liter/HR 0.01
Lube oil change Period HRS 600
Lub Oil system capacity (with filters) Liters 6
Aspiration   Natural
Battery  Volts Volts 12
Battery Capacity AH 88
CANOPY Length mm 2120
width mm 900
Height mm 1410
weight kg 800
Fuel tank capacity Liters 134
SERVICE COST Fuel filter Cost Rs 212
oil filter cost Rs 179
oil cost Rs 1260
Total   1651

Mahindra DG SET

  • Foil Print

Get Latest Price

Product Brochure
Power (kVA)10
Genset BrandMahindra Powerol
Model Number2185 GM-C2
Engine MakeMahindra
PhaseThree & Single
Fuel Consumption (at 100% Load)NA
Fuel Tank CapacityNA
AMCAvailable
On-site ServiceAvailable
Country of OriginMade in India

Minimum order quantity: 1 Number

Sr. No. Specification Quantity Mahindra
  Engine Model   2185GM C2
ENGINE No Of Cylinders   2
BHP HP 18
RPM RPM 1500
Stroke   4
Bore *Stroke  MM 88.9*110
Displacement CC 1.365
Compression Ratio   19.4:1
Governing system   A1
Cooling System    Water Cooled
Cooling System Coolant Capacity  Liters 9.5
Fuel consumption at 100% in Ltr/Hr Liters 2.9
Fuel consumption  at 75% in Ltr/Hr Liters 2.38
Fuel consumption  at 50% in Ltr/Hr Liters 1.68
Lube oil consumption Liter/HR 0.01
Lube oil change Period HRS 600
Lub Oil system capacity (with filters) Liters 5.5
Aspiration   Natural
Battery  Volts Volts 12
Battery Capacity AH 88
CANOPY Length mm 1800
width mm 900
Height mm 1290
weight kg 700
Fuel tank capacity Liters 100
SERVICE COST Fuel filter Cost Rs 212
oil filter cost Rs 179
oil cost Rs 1155
Total Rs 1546

MAHINDRA Automatic Generator

  • Foil Print

Get Latest Price

Product Brochure
Power (kVA)25
Genset BrandMahindra
Engine MakeMahindra
PhaseSingle & Three
Fuel TypeDiesel
Usage/ApplicationAll
Voltage415
Power0.8 power factor
I Deal InNew Only

Minimum order quantity: 1 Number

Sr. No. Specification Quantity Mahindra
  Engine Model   3385GM C2
ENGINE No Of Cylinders   3
BHP HP 38
RPM RPM 1500
Stroke   4
Bore *Stroke  MM 88.9 x 101.6
Displacement CC 1.89
Compression Ratio   19.5:1
Governing system   A1
Cooling System    Water Cooled
Cooling System Coolant Capacity  Liters 9.5
Fuel consumption at 100% in Ltr/Hr Liters 6.2
Fuel consumption  at 75% in Ltr/Hr Liters 4.7
Fuel consumption  at 50% in Ltr/Hr Liters 3.6
Lube oil consumption Liter/HR 0.01
Lube oil change Period HRS 600
Lub Oil system capacity (with filters) Liters 6
Aspiration   TC
Battery  Volts Volts 12
Battery Capacity AH 100
CANOPY Length mm 2500
width mm 1030
Height mm 1376
weight kg 940
Fuel tank capacity Liters 134
SERVICE COST Fuel filter Cost Rs 212
oil filter cost Rs 243
oil cost Rs 1260
Total   1715

Mahindra Silent Generators

  • Foil Print

Get Latest Price

Product Brochure
Power (kVA)25
Genset BrandMahindra
Engine MakeMahindra
PhaseThree & Single
Fuel Consumption (at 100% Load)NA
Model NumberNA
Fuel Tank CapacityNA
AMCAvailable
On-site ServiceAvailable
Dry Weight (Kg)1050 kg (Approx.)

Minimum order quantity: 1 Number

Sr. No. Specification Quantity Mahindra
  Engine Model   3385GM C2
ENGINE No Of Cylinders   3
BHP HP 38
RPM RPM 1500
Stroke   4
Bore *Stroke  MM 88.9 x 101.6
Displacement CC 1.89
Compression Ratio   19.5:1
Governing system   A1
Cooling System    Water Cooled
Cooling System Coolant Capacity  Liters 9.5
Fuel consumption at 100% in Ltr/Hr Liters 6.2
Fuel consumption  at 75% in Ltr/Hr Liters 4.7
Fuel consumption  at 50% in Ltr/Hr Liters 3.6
Lube oil consumption Liter/HR 0.01
Lube oil change Period HRS 600
Lub Oil system capacity (with filters) Liters 6
Aspiration   TC
Battery  Volts Volts 12
Battery Capacity AH 100
CANOPY Length mm 2500
width mm 1030
Height mm 1376
weight kg 940
Fuel tank capacity Liters 134
SERVICE COST Fuel filter Cost Rs 212
oil filter cost Rs 243
oil cost Rs 1260
Total   1715

Mahindra Diesel Engine Generator Set

  • Foil Print

Get Latest Price

Product Brochure
Power (kVA)45 (4575 TCI GM- C2 )
Genset BrandMahindra
Engine MakeMahindra
Phase3-Phase
Fuel Consumption (at 100% Load)NA
Centre lifting DG set dimensions with top hoodNA
Side lifting DG set dimensions with top hoodNA
Dimensions (W x H x D)NA
Lube Oil Change PeriodNA
Bore x Stroke (mm)NA

Minimum order quantity: 1 Number

Sr. No. Description Unit  
1 New Name after Emission Certification   4575 TCIGM-C2
2 No Of Cylinders Qty 4
3 Gross Engine bhp  hp 57
4 Typical Alternator Efficiency % age 90
5 Stroke   4 Stroke 
6 BORE / STROKE mm / mm 88.9 X 110
7 Displacement cc 2730
8 Compression Ratio   19.4 : 1
9 Unit Dry Wt of Bare Engine Kg kg 280
10 Flywheel Housing / Flywheel SAE 03-Oct
11 Direction of Rotation from Flywheel end   Counter Clock wise
12 Firing Order Seq 1 - 3 - 4 - 2 
13 Mechanical efficiency % age 85
14 Thermal  efficiency % age 42%
15 Reference Standard REF BS 5514
16 Governing system   Electronic
17 Type of Governor
18 Class  Of Governor   A 1
19 Engine Speed Droop ( Governing ) % age 4%
20 Maximum allowable Engine Overspeed rpm 1650
21 Heat Rejection to atmosphere (Cooling + Exhaust) kW 74

62.5 kva mahindra engine diesel genrator set

  • Foil Print

₹ 7.54 Lakh /Piece Get Latest Price

Product Brochure

Silence is Golden: India’s most silent Genset brand

Mahindra Powerol’s ‘Spectro’ series of diesel gensets is one of the most silent gensets manufactured by the brand. It has sturdy wheels and a long handle which allows easy mobility of the genset.

Mahindra Mobile Lighting Tower 10KVA Powerol Genset

Get Latest Price

Product Brochure
Height9m
Usage/ApplicationOutdoor
Fuel TypeDiesel
Voltage415V
Power10KVA
Lighting ColorWhite
Number Of Phase3 Phase
Country of OriginMade in India
BrandMahindra

While power cuts eat into your profits, an inefficient DG set will simply add to your losses. Powered by Powerol engines, Mahindra Powerol DG sets have been designed to ensure you an efficient power supply. This also assures you years of hassle-free operations with Mahindra Powerol Diesel Generators. Product range available: 5 kVA to 625 kVA.

Mahindra Power Generator

Get Latest Price

Product Brochure
Power (kVA)50 (4725 GM- C2 )
Genset BrandMahindra
Engine MakeMahindra
Phase3-Phase
Fuel Consumption (at 100% Load)NA
Centre lifting DG set dimensions with top hoodNA
Side lifting DG set dimensions with top hoodNA
Dimensions (W x H x D)NA
Lube Oil Change PeriodNA
Bore x Stroke (mm)NA

Minimum order quantity: 1 Number

Sr. No. Specification Quantity Mahindra
  Engine Model   4725GM C2
ENGINE No Of Cylinders   4
BHP HP 72
RPM RPM 1500
Stroke   4
Bore *Stroke  MM 94X115
Displacement CC 3.2
Compression Ratio   19.5:1
Governing system   A1
Cooling System Coolant Capacity    Water Cooled
Cooling System Coolant Capacity  Liters 15
Fuel consumption at 100% in Ltr/Hr Liters 11.72
Fuel consumption  at 75% in Ltr/Hr Liters 8.58
Fuel consumption  at 50% in Ltr/Hr Liters 5.85
Lube oil consumption Liter/HR 0.01
Lube oil change Period HRS 600
Lub Oil system capacity (with filters) Liters 8.5
Aspiration   TC
Battery  Volts Volts 12
Battery Capacity AH 120
CANOPY Length mm 2770
width mm 1150
Height mm 1800
weight kg 1250
Fuel tank capacity Liters 200
SERVICE COST Fuel filter Cost Rs 212
oil filter cost Rs 283
oil cost Rs 1785
Total   2280

X

Contact Us

TANWAR INDUSTRIES (Partner)
Tanwar Industries
B-159, TANWAR INDUSTRIES, RIICO INDUSTRIAL AREA, MANDA CHOMU, Jaipur
Jalupura, Jaipur - 302013, Rajasthan, India

Get Directions
Send Email
Share:
Thank youYour Enquiry has been sent successfully.